Abstract
A simple, precise and sensitive reverse-phase high performance liquid chromatographic (RP-HPLC) method has been developed for the quantitation of Escitalopram oxalate in pharmaceutical formulations. Chromatographic separation was achieved on a 250 × 4.6 mm, 5μ, C18 column. The flow rate was 1ml/min and eluent was monitored by absorbance at 240 nm using a mixture of Acetonitrile and Buffer (pH 4.0) in the ratio of 25:75 (v/v). The retention times of Escitalopram oxalate was found to be 3.2 min. Calibration plots were linear in the concentration range of 2.5-80 μg mL-1 for Escitalopram oxalate. The total run time is 10 min. The proposed method was validated by testing its linearity, recovery, specificity, system suitability, precision (Interday and intraday), robustness and LOD/LOQ values and it was successfully employed for the determination of Escitalopram oxalate in pharmaceutical tablet formulations.
Keywords
Full Text:
DOI: https://doi.org/10.7439/ijpc.v2i1.422
Refbacks
- There are currently no refbacks.
Copyright (c) 2014 International Journal of Pharmaceutical Chemistry
This work is licensed under a Creative Commons Attribution 4.0 International License.